Installation manual
Operation Manual - System Management
Quidway S3000-EI Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-9
1) Sending the configuration information to loghost.
Table 4-13 Sending the configuration information to loghost
Device Configuration Default value Configuration description
Enable info-center
By default,
info-center is
enabled.
Other configurations are valid
only if the info-center is enabled.
Set the information
output direction to
loghost
-
The configuration about the
loghost on the switch and that on
loghost must be the same;
otherwise the information cannot
be sent to the loghost correctly.
Switch
Set information
source
-
You can define which modules
and information to be sent out
and the time-stamp format of
information, and so on. You
must turn on the switch of the
corresponding module before
defining output debugging
information.
Loghost
Refer to
configuration cases
for related log host
configuration
- -
2) Sending the configuration information to the console terminal.
Table 4-14 Sending the configuration information to the console terminal.
Device Configuration Default value Configuration description
Enable info-center
By default,
info-center is
enabled.
Other configurations are valid
only if the info-center is enabled.
Set the information
output direction to
Console
- -
Set information
source
-
You can define which modules
and information to be sent out
and the time-stamp format of
information, and so on. You
must turn on the switch of the
corresponding module before
defining output debugging
information.
Switch
Enable terminal
display function
-
You can view debugging
information after enabling
terminal display function