QuickVue iFOB TEST
Place six (6) drops
in center of well
INTERPRETATION OF RESULTS
Refer to the Procedure Card or printed tray for visual color interpretation of the Test and
Control Lines. Both the T-line and the C-line present as the same burgundy color.
Positive Result:
If both a C-line and a T-line are present, the result is positive. A positive
result indicates the level of hHb in the specimen is at or above the
detection level.
Negative Result:
If only the C-line develops in the control region of the test strip, the
result is negative.
Invalid Result:
If no C-line appears within 5 minutes, the result is invalid and
the assay should be repeated with a new device. NOTE: The test
line may or may not be present. However, the absence of a control
line indicates an invalid test.
IMPORTANT: Do not read the test results after ten (10) minutes.
Q UICK LY snap off tip.
DO NOT TWIST.
Holding the Collection Tube vertically, dispense
six (6) drops of specimen solution from the
Collection Tube into the center of the Sample
Well.
READ RESULTS AT 5–10 MINUTES.
Some positive results may be seen earlier.
C
T
iFOB
x6
Squeeze Here
SNAP AWAY