Instructions / Assembly
Shaftwall
29
INTERIOR FRAMING
The technical content of this literature is eective 5/31/12 and supersedes all previous information. Pub. No. CD-Full Line 5/12
clarkdietrich.com
CT SHAFTWALL/STAIRWELL STUD
Engineered to maintain shaftwall 
integrity, ClarkDietrich CT cavity 
shaftwall studs are punched with 
1" circular knockouts at 12" o.c. for 
easy installation of conduit or other 
mechanical service lines.
Independent laboratory tests have 
demonstrated that the slotting in 
the web improves resistance to 
thermal and noise transmissions 
eectively.
Product
code
Thickness
Stud
depth
(in)
Gauge Mils
Design
thickness (in)
CTN2 25 21 0.0230 2-1/2
CTE2 20 33 0.0346 2-1/2
CTN4 25 21 0.0230 4
CTE4 20 33 0.0346 4
CTE6 20 33 0.0346 6
For installations requiring compliance with NER506, special order products are required.
JTABBED TRACK/JRUNNER
ClarkDietrich J-tabbed track is 
used at the floor and ceiling in 
shaftwall assemblies. CT-studs 
and gypsum shaftliner panels are 
friction fit between the top and 
bottom J-tabbed track. J-tabbed 
tracks have unequal legs with the 
longer leg (available in 2-1/4" and 
3") installed against the shaft. The 
leg provides a backstop for easy 
installation of the shaftliner. Three-
inch leg track is typically used as 
jamb struts around closure details, 
including duct and door openings, 
abutments and intersections.
ClarkDietrich J-tabbed track is 
punched with fold-up tabs every 
12," permitting faster, more ecient 
installation.
Product
code
Thickness Size
Gauge Mils
Design 
thickness
(in)
Width  
(in)
Leg 
(in)
TTN (2,3)* 25 21 0.0230
2-1/2
2-1/4
3
4
2-1/4
3
TTE (2,3)* 20 33 0.0346
2-1/2
2-1/4
3
4
2-1/4
3
6
2-1/4
3
*2 designates 2-1/4" leg; 3 designates 3" leg. 
Note: Revised ICC Report pending.