Instructions / Assembly
INTERIOR FRAMING
The technical content of this literature is eective 5/31/12 and supersedes all previous information. Pub. No. CD-Full Line 5/12
clarkdietrich.com
Product 
code
Thickness
Size (in)
Length 
(ft)
Gauge Mils
Design 
thickness (in)
RCUR 23 22 0.0232 1-1/4 12
Made of 22mil steel, RC-1 ProPlus is used as a cross-
furring member for resilient attachment of gypsum. 
Knurled face makes wallboard application easier.
RC-1 ProPlus single-leg resilient channel is typically 
used for applications with multiple layers of 
gypsum board. Resilient channel should be installed 
perpendicular to the framing members with the 
attachment flange of the RC-1 ProPlus installed 
along the bottom edge. Channel is prepunched 
for screw attachments to wood or steel framing 
members. Nails are not recommended.
Gypsum 
type
Side A Side B
Insulation 
type
Stud depth
(in)
Stud 
spacing
(in)
STC Rating
ProSTUD
®
25
WEAL test no.
5/8"  
Type X
1 layer
1 layer on  
RC-1 Pro Plus
R-13 
unfaced*
3-5/8 24 53 TL10-504
5/8"  
Type X
1 layer
2 layers on 
RC-1 Pro Plus
R-13 
unfaced*
3-5/8 24 58 TL10-505
5/8"  
Type X
2 layers
2 layers on 
RC-1 Pro Plus
R-13 
unfaced*
3-5/8 24 63 TL10-506
Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
RC1  ProPlus HEAVYDUTY RESILIENT CHANNEL
RC2 PRO DOUBLELEG RESILIENT CHANNEL
Product 
code
Thickness
Size 
(in)
Length 
(ft)
Gauge Mils
Design 
thickness (in)
RCDN 25 18 0.0188 1-1/4 12
Made of 25 gauge steel, RC-2 Pro double-leg 
resilient channel is typically used for ceiling 
applications. It is used as a cross-furring member 
for resilient attachment of gypsum. Knurled 
face makes wallboard application easier.
Resilient channel should be installed 
perpendicular to the framing members. 
Channel is prepunched for screw attachments 
to wood or steel framing members.
Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
Gypsum 
type
Side A Side B
Insulation 
type
Stud 
depth
(in)
Stud 
spacing
(in)
STC Rating
ProSTUD 
25
WEAL test no.
5/8"  
Type X
1 layer
1 layer on  
RC-2 Pro
R-13 
unfaced*
3-5/8 24 52 TL10-513
5/8"  
Type X
1 layer
2 layers on 
RC-2 Pro
R-13 
unfaced*
3-5/8 24 58 TL10-514
5/8"  
Type X
2 layers
2 layers on 
RC-2 Pro
R-13 
unfaced*
3-5/8 24 62 TL10-515
Product 
code
Thickness
Size 
(in)
Length 
(ft)
Gauge Mils
Design 
thickness (in)
RCDE 23 22 0.0232 1-1/4 12
Sound assemblies are certified by Western Electro-Acoustic Laboratories.
NVLAP accredited for ASTM E90 & E413, ISO Certified.
Additional test reports available through ClarkDietrich Technical Services.
*Values are the same for R-11 insulation.
Made of 30mil steel to provide a stier resilient 
channel, RC-2 ProPlus heavy-duty double-
leg resilient channel is typically used for ceiling 
applications with multiple layers of gypsum board. 
It is used as a cross-furring member for resilient 
attachment of gypsum. Knurled face makes wallboard 
application easier.
Resilient channel should be installed perpendicular 
to the framing members. Channel is prepunched for 
screw attachments to wood or steel framing members.
Gypsum  
type
Side A Side B
Insulation 
type
Stud 
depth
(in)
Stud 
spacing
(in)
STC Rating
ProSTUD  
25
WEAL test no.
5/8"  
Type X
1 layer
1 layer on  
RC-2 Pro Plus
R-13 
unfaced*
3-5/8 24 53 TL10-518
5/8"  
Type X
1 layer
2 layers on  
RC-2 Pro Plus
R-13 
unfaced*
3-5/8 24 58 TL10-517
5/8"  
Type X
2 layers
2 layers on  
RC-2 Pro Plus
R-13 
unfaced*
3-5/8 24 62 TL10-516
RC2  ProPlus HEAVYDUTY DOUBLELEG RESILIENT CHANNEL
17
SOUND-RATED SYSTEMS