Instructions / Assembly
Table Of Contents
- QuickJack Manual
- Table of Contents
- Introduction
- Shipping
- Safety
- Components
- Accessories
- Specifications
- Frequently Asked Questions
- Setup Checklist
- Setup
- Setup Safety Rules
- Tools
- Selecting a Site
- Unpacking
- Clearances
- QuickJack Assembly Kit
- Air and Hydraulic Cylinders
- Installing the Hydraulic Elbow Fittings
- Preparing the Short Hydraulic Hoses
- About Quick-Connect Fittings
- Routing the Short Hydraulic Hoses
- Preparing and Connecting the Long Hydraulic Hoses
- Pressurizing the Air Cylinders
- Find a Location for the Power Unit
- Installing the Hydraulic Fittings on the Power Unit
- Connect the Power Unit to a Power Source
- Filling the Hydraulic Fluid Reservoir on the Power Unit
- Check the Breather Valve
- Connect the Hydraulic Hoses
- Bleeding the Hydraulic Cylinders
- Final Checklist Before Operation
- Test the QuickJack
- Leave the Manual with the Owner/Operator
- Operation
- Maintenance
- Troubleshooting
- Wiring Diagrams
- Labels
- Parts Sheets
- Automotive Lift Institute (ALI) Store
- Maintenance Log
- CE Documentation
QuickJack™ Portable Car Jack 24 P/N 5900959 — Rev. J3 — Oct. 2019
Preparing and Connecting the Long Hydraulic Hoses
Your QuickJack comes with two Long Hydraulic Hoses:
• One end attaches to the Short Hydraulic Hose
• The other end attaches to the Power Unit
Both ends require the installation of a female Quick-Connect Fitting.
To prepare and connect your Long Hydraulic Hoses:
1. Locate both Long Hydraulic Hoses and remove their protective caps.
2. Wrap all four threaded ends with Thread Seal Tape.
Wrap the Thread Seal Tape in the same direction you will be turning the fittings.
3. Take all four female Quick-Connect Fittings from the QuickJack Assembly Kit.
4. Connect the female Quick-Connect Fittings to the male threaded connectors on both ends of both
Long Hydraulic Hoses; four connections in total.
To tighten, use one wrench to hold the Male connector in place and a second wrench on the
Female Quick-Connect Fitting to tighten it; tighten to 10 to 11 lbf-ft / 13 to 15 N-m.