Instructions / Assembly

Table Of Contents
QuickJack™ Portable Car Jack 29 P/N 5900263Rev. B1 — September 2021
Filling the Hydraulic Fluid Reservoir on the Power Unit
The Hydraulic Fluid Reservoir must be filled with Hydraulic Fluid or Automatic Transmission Fluid
before
you begin operation of the QuickJack.
When you receive it, the Fluid Reservoir is empty.
The Power Unit will not work correctly
until it is filled with approved fluids.
The fluid level should be approximately .5 inch (12 mm) below the Fill Hole when the QuickJack is fully
lowered.
CAUTION If you use the QuickJack
without
fluid in the reservoir, you could damage the
Power Unit.
WARNING Hydraulic Fluid under pressure is dangerous. You must wear OSHA-approved
(publication 3151) Personal Protective Equipment
at all times
when handling
hydraulic components: eye protection and leather gloves are mandatory.
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 Hydraulic Fluid, approved
Automatic Transmission Fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
multi-vehicle Automatic Transmission Fluid.
Note: The fluid level drops some after you start using the QuickJack; this is because some fluid
stays in the Hydraulic Hoses. If you notice that the fluid level has dropped more than a little,
you should fill it back up to half an inch below the Fill Hole (with the Frames on the ground).
Important: Do not completely fill the Fluid Reservoir while there is fluid in the hoses. If you do, the
Reservoir could overflow when the fluid in the hoses returns (when you lower the
QuickJack Frames).
QuickJack recommends having a couple of rags nearby in case any fluid leaks.