Full Product Manual

OVERBUILT, NOT OVERPRICED.
System
1.1 The ttings and valves shall be of the push to
connect type (Manufacturer - Quick Fitting Holding
Co.) and shall be manufactured to the quality
system of ISO 9001.
1.2 The system shall be full bore passage without
diameter restriction for the ttings, in order to
avoid high pressure-drop.
Pipe
2.1 Copper pipe shall conform to ASTM B-88 and
may be type K, L, or M seamless copper.
2.2 CPVC pipe shall conform to ASTM D2846, CSA
B137.6.
2.3 PEX tubing shall conform to ASTM F-876,
CSA B137.5. Tube support liners provided by Quick
Fitting, Inc. shall be used.
2.4 Plumbing systems must be installed in
compliance with local plumbing code.
Fittings & Valves
3.1 Fittings and valves shall have a maximum
operating pressure of 200 PSI at a maximum
continuous operating temperature of 200°F. Higher
temperatures and pressures may be permissible;
please consult with manufacturer.
3.2 Fittings shall utilize copper alloy bodies
meeting ASTM B-283 standard with stainless steel
gripping teeth and shall use EPDM seals that are
certied to NSF-61 service.
3.3 Fittings and valves shall incorporate a one-step
connection method: push-to-connect, no pre-
lubrication required.
3.4 Fittings and valves shall permit 360° rotation of
the pipe while system is depressurized.
3.5 Fittings and valves shall be removable
and reusable with the use of a removal tool
(Manufacturer - QuickFitting Holding Co.)
3.6 Fittings shall use NSF/ANSI/CAN 61-2020 and
NSF/ANSI/CAN 372-2020 approved pre-lubricated
EPDM seals so that additional lubrication or tting
preparation is not needed.
3.7 Fittings shall be design certied to ASSE-1061,
NSF/ANSI/CAN 61-2020, and NSF/ANSI/CAN 372-
2020.
System Installation
4.1 Fittings shall be installed according to Quick
Fitting installation instructions.
4.2 Pipe ends shall be chamfered, de-burred,
reamed, and depth marked prior to tting or valve
installation. When cutting tubing, ensure that the
ends are cut square and are free of burrs.
4.3 Ensure that there are no scratches, gouges
or any form of damage on the circumference of
the tube within the specied depth on Table 1.1.
Damage in this area may cause leakage. Check the
tting for any signs of damage or foreign objects.
Push the QuickFitting tting or valve onto the end
of the copper pipe until depth mark is covered.
Insertion Depth Table
4.4 Use only in accordance with Quick Fitting’s
specications and operating instructions.
4.5 If PEX tubing is used, then a tube support liner
must be used also. The tube support liner acts as
an internal support for the end of the tubing.
4.6 When a joint has to be disassembled and then
re-used, ensure that the tubing removed from
the joint has no damage on the circumference
within the specied depth on Table 1.1. Inspect the
tube and connection for any signs of damage and
ensure they are free of foreign materials. The joint
can then be reassembled.
4.7 Installations shall be pressure tested to ensure
proper insertion of the push ttings and valves.
4.8 Installers shall never use pliers or crush the
push connect head of the tting.
19
QuickFitting Holding Company, LLC.
655 Waterman Ave., East Providence, RI 02914
Tel: (877) 238-4826 • Fax: (877) 258-4826
3/4” 3/4” 1”
1-3/16” 1-3/16” 1-7/8” 2-1/8 2-3/16”