The lightning threa level is  derived  from  the  lightning  detector and expresses a 
threat  level  indicating  the  need  to  run  generators  up  to  storm  stowing  the 
telescope. 
9.3.4.  Severe lightning threat with generator off 
Message ID:  10 
Triggers when:  The generator is not running and the threat level is greater 
  than 2 
Indicates possibly a failed generator start. Give the generator ample time to start 
running, on the order of 5 minutes. 
9.3.5.  Focus disagree 
Message ID:  15 
Triggers when:  The difference between the actual and the requested focus 
  position is greater than 1.0mm and the requested focus 
  position is not 1000.0, the value it reverts to after an 
  atdaemonrestart 
9.3.6.  ACC CPU load high 
Message ID:  16 
Triggers when:  CPU load of ACC is greater than 98% 
9.3.7.  ACC unreachable 
Message ID:  18 
Triggers when:  the  ACC  is  not  pingable  from  bigrock  for  three  consecutive 
pings 
9.3.8.  Drive Error in AzEl exceeds 1 minute 
Message ID: 19 
Triggers when:  the drive error in azimuth or elevation is larger than 1 minute 
  and it persists for more than 2 consecutive data polls 
  (i.e. 10 seconds). 
This error can hint at tracking problems. 
9.3.9.  Drive Error 
Message ID:  20 
Triggers when:  the drive error condition persists for more than 2 consecutive 
  Data polls (i.e. 10 seconds). 