6.4.2.  Via MAPS reset button 
•  Walk to the MAPS panel in the PMON rack at Narrabri (this obviously only 
works if you’re on site in Narrabri) 
•  Press the button labelled “ACC Reset” for at least 30 seconds (you will 
need a watch) and give it a minute to reboot 
Once the ACC has rebooted, it automatically becomes available and the required 
setup information is automatically furnished to the ACC. 
6.5.  MOPS programming errors 
MOPS  sometimes  does  not  properly  complete  its  own  programming.  In  such 
cases, a terminal window that  was  displaying  the  progress  will remain open on 
top of the MOPS  window,  so  it  will  be immediately obvious that something  has 
gone wrong. 
Simply click the mouse into that terminal, hit [RETURN] and then type “prog” and 
hit [RETURN]”. The  programming will  restart. If it  fails again, repeat  until it 
worked. 
Figure 23 MOPS programming error 