User manual
Transponder Access Control Kit
Version: 1.0 4
(6) Key “5”: Door open time setting
Press “5” → input time → press “ENT” → press “9” to exit
The time format is “**”, e.g. “03” represents that the open time is 3 seconds.
When time is set as 99 seconds; the open method is trigger mode (presenting card
and the door open. Presenting the card again, then the door close.
(7) Key “6”: setup the door open password
(the factory default open password is blank)
Door open password setting: Press “6” → input the new password → press “ENT” → input
password again →press “ENT” → press “9” to exit
Blank password setting: Press “6” →press “ENT” →press “ENT” → press “9” to exit
This password can be used in Card or Password Mode and Password Mode.
It must have 6 digits.
If it is blank password setting, the password mode can not be used. (Can not open the
door via password).
3. The exit key is “9”
4. The doorbell key is “DOORBELL”
5. Modify card password (should operate in the Card and Password Mode)
Press “9”( the red light is off and the green light is on) → present the card( must be authorized
cards) →input the original password( the original password is 888888) → press “ENT” → input
new password → press “ENT” → input password again → press ‘ENT”
This password is only valid in Card and Password Mode.
If modify successfully, the buzzer makes 2 “di-di” short sounds, then it will exit the
Program Mode.
6. Restore to factory default setting
(only restore the program passwords and parameter settings. Authorized cards
will not be deleted)
With power off, short the JP1 jumper to 2 and 3 position. Then with power on, after hearing 2
“di-di” sounds, short the JP1 jumper to 1 and 2 positions. Then modify successfully.