Datasheet
113730 © NXP B.V. 2007. All rights reserved.
Product data sheet Rev. 3.0 — 14 March 2007 9 of 33
NXP Semiconductors
SL2 ICS53/SL2 ICS54
I•CODE SLI-S/I•CODE SLI-S HC
PUBLIC
7.3 Communication principle
ISO/IEC 15693 command set
For detailed description of the protocol and timing please refer to ISO/IEC 15693-2
(modulation, bit-coding, framing) and 15693-3 (anticollision, timing, protocol).
EPC command set
For detailed description of the protocol and timing please refer to EPC Specification
“13.56
MHz ISM Band Class 1 Radio Frequency (RF) Identification Tag Interface
Specification”.
8. Command set
8.1 ISO/IEC 15693 command set
8.1.1 Mandatory commands
8.1.1.1 Inventory
As defined in ISO/IEC 15693-3.
Exception: If the Privacy or Destroy mode is enabled the label will not respond.
8.1.1.2 Stay Quiet
As defined in ISO/IEC 15693-3.
8.1.2 Optional Commands
8.1.2.1 Read Single Block
As defined in ISO/IEC 15693-3.
Option 0 (Option flag not set) is supported.
Option 1 (Option flag set) is supported.
If the Privacy or Destroy mode is enabled the label will not respond.
If the related page of the addressed block is protected with the Read-Password and the
password has not been transmitted before with the Set Password command the label will
respond according to the error handling (see
Section 8.4 “Error handling”).
8.1.2.2 Write Single Block
Only Option 0 (Option flag is not set) is supported.
If the addressed block is part of a write protected page or only protected with the Read
Password (see
Section 8.1.3.6 “Protect page”) and the password has not been
transmitted before with the Set Password command the label will respond according to
the error handling (see
Section 8.4 “Error handling”).