Datasheet

113730 © NXP B.V. 2007. All rights reserved.
Product data sheet Rev. 3.0 — 14 March 2007 8 of 33
NXP Semiconductors
SL2 ICS53/SL2 ICS54
I•CODE SLI-S/I•CODE SLI-S HC
PUBLIC
7.2.1 Unique Identifier
The 64-bit unique identifier (UID) is programmed during the production process according
to ISO/IEC
15693-3 and cannot be changed afterwards.
The numbering of the 64 bits is done according to ISO/IEC 15693-3 starting with the
LSB
1 and ending with the MSB 64. This is in contrast to the general used bit numbering
within a byte (starting with LSB
0).
The TAG type is a part of the UID (bit 41 to 48, after the manufacturer code which is “04h”
for NXP Semiconductors).
The TAG type of the SL2 ICS53/SL2 ICS54 is “02h”
Table 4. Unique Identifier description
Byte 7 6 5 4 3 2 1 0
Name UID 7 UID 6 UID 5 UID 4 UID 3 UID 2 UID 1 UID 0
Value E0 04 02 IC manufacturer serial number
Bit 64 to 57 56 to 49 48 to 41 40 to 1
MSB LSB
7.2.2 Configuration of delivered ICs
I•CODE SLI-S/I•CODE SLI-S HC ICs are delivered with the following configuration by
NXP Semiconductors:
Unique Identifier is unique and read only
Write Access Conditions allow to change user blocks, AFI, DSFID, EAS and
Passwords
All password bytes are 00h (Protection Password, Privacy Password, Destroy
Password, EAS Password)
User Data memory is not password protected
Password protected Privacy Mode is disabled
EAS password protection is disabled
Status of EAS mode is not defined
AFI is supported and not defined
DSFID is supported and not defined
EPC Memory is not defined and can be written once
User Data memory is not defined