Datasheet
113730 © NXP B.V. 2007. All rights reserved.
Product data sheet Rev. 3.0 — 14 March 2007 8 of 33
NXP Semiconductors
SL2 ICS53/SL2 ICS54
I•CODE SLI-S/I•CODE SLI-S HC
PUBLIC
7.2.1 Unique Identifier
The 64-bit unique identifier (UID) is programmed during the production process according
to ISO/IEC
15693-3 and cannot be changed afterwards.
The numbering of the 64 bits is done according to ISO/IEC 15693-3 starting with the
LSB
1 and ending with the MSB 64. This is in contrast to the general used bit numbering
within a byte (starting with LSB
0).
The TAG type is a part of the UID (bit 41 to 48, after the manufacturer code which is “04h”
for NXP Semiconductors).
The TAG type of the SL2 ICS53/SL2 ICS54 is “02h”
Table 4. Unique Identifier description
Byte 7 6 5 4 3 2 1 0
Name UID 7 UID 6 UID 5 UID 4 UID 3 UID 2 UID 1 UID 0
Value E0 04 02 IC manufacturer serial number
Bit 64 to 57 56 to 49 48 to 41 40 to 1
MSB LSB
7.2.2 Configuration of delivered ICs
I•CODE SLI-S/I•CODE SLI-S HC ICs are delivered with the following configuration by
NXP Semiconductors:
• Unique Identifier is unique and read only
• Write Access Conditions allow to change user blocks, AFI, DSFID, EAS and
Passwords
• All password bytes are 00h (Protection Password, Privacy Password, Destroy
Password, EAS Password)
• User Data memory is not password protected
• Password protected Privacy Mode is disabled
• EAS password protection is disabled
• Status of EAS mode is not defined
• AFI is supported and not defined
• DSFID is supported and not defined
• EPC Memory is not defined and can be written once
• User Data memory is not defined