User Manual

37
QNC CHC
EN
INSTALLATION AND USE MANUAL - REV 001A
SPEED: 0 m/min
SLEEP MODE function sets the instrument to a low consumption status. The detection of lowered chain measurement
remains active in the background.
4.0 - INSTRUMENT CONFIGURATION
4.5 - Sleep mode
4.6 - Gypsy circumference measurement
Press and hold
key until the display is off
(approx. 5 seconds).
Mark a reference on the chain and the gypsy
on the main axis.
F
Make one complete lap of the gypsy, returning
its reference to the initial position.
Measure the chain length between the main
axis and the position reached by the reference
after a complete gypsy lap.
The accuracy of the value set as GYPSY
LAP affects the precision of lowered chain
measurement.
REFERENCE
ON THE CHAIN
REFERENCE
ON THE CHAIN
GYPSY LAP
REFERENCE
ON THE GYPSY
REFERENCE
ON THE GYPSY
To determine the chain length obtained with each gypsy lap, proceed as follows: