User Manual

36
QNC CHC
EN
INSTALLATION AND USE MANUAL - REV 001A
4.0 - INSTRUMENT CONFIGURATION
NEXT
SELECT
PREV
ADVANCED SETTINGS
MANUAL CALIBRATION
AUTOMATIC CALIBRATION
CHAIN ON BOARD
AUTOMATIC FREE FALL
NETWORK SETTINGS
FACTORY DATA RESET
< BACK
DEC
SAVE
INC
GYPSY LAP
inch
MANUAL CALIBRATION
1/2
039,30
MAGNETS NUMBER
MANUAL CALIBRATION
2/2
01
DEC
SAVE
INC
4.4 - Exit from icon menu
NEXT
SELECT
PREV
MENU
HOME
4.3 - Calibration
NEXT
SELECT
PREV
MENU
ADVANCED SETTINGS
Advanced settings
Select MANUAL CALIBRATION
Press
Menu
Select HOME ICON
Press
to return to the main screen.
Manual calibration
GYPSY LAP
Enter gypsy lap value (in cm or inches) according to the unit of measurement
previously selected (meters or feet/fathoms).
Selectable values 10 to 600 cm (factory setting 10 cm).
Selectable values 3.93 to 236.22 inches (factory setting 3.93 inches).
Enter the value by pressing
p
to increase or
q
to decrease.
Press to select the next box.
MAGNETS NUMBER
Selectable values 1 to 16 (factory setting 1)
Enter the value by pressing
p
to increase or
q
to decrease.
Press to select the next box.
Confirmation of the last box takes back to the ADVANCED SETTINGS menu.
Select “BACK” and press
to
return to the menu.
Menu
Select ADVANCED SETTINGS
Press