Instruction Manual

PONTOON 350 - 700 - 1000 - REV003A
TECHNICAL DATA
EN
14
(1) After an initial period of use.
(2) Measurements taken with rope 6 mm.
(3) Minimum allowable value for a total length L= < 20m (see connection diagrams). Determine the cable size according to the length of the wiring.
(4) With circuit breaker designed for direct currents (DC) and delayed-action (thermal-magnetic or hydraulic-magnetic).
(5) On request, studs can be supplied for greater deck thicknesses.
Quick
®
reserves the right to introduce changes to the equipment and the contents of this manual without prior notice.
In case of discordance or errors in translation between the translated version and the original text in the Italian language, reference will be made to the Italian or English text.
F
294 (11
37
/64)
173 (6
13
/16)
220 (8
43
/
64
)
596 (23
29
/64)
308 (12
9
/64)
231 (9
7
/64)
148 (5
53
/
64
)
220 (8
43
/64)
294 (11
37
/
64
)
173 (6
13
/16)
220 (8
43
/
64
)
PT 350 R - PT 700 R - PT 1000 R
PTR WITH BOW-ROLLER ACCESSORY (ONLY MODELS 350 - 1000)
PT 350 G - PT 700 G - PT 1000 G
MODELS PONTOON
PT 350 R - PT 350 G PT 700 R - PT 700 G PT 1000 R - PT 1000 G
MOTOR OUTPUT
150 W 250 W 350 W
MOTOR SUPPLY VOLTAGE 12 V 12 V 24 V
Maximum pull 260 kg (573,2 lb) 600 kg (1322,7 lb) 750 kg (1653,4 lb)
Maximum working load 100 kg (220,4 lb) 220 kg (485,0 lb) 250 kg (551,0 lb)
Working load 40 kg (88,1 lb) 80 kg (176,3 lb) 100 kg (220,4 lb)
Current absorption @ working load (1) 13 A 22 A 16 A
Maximum chain speed (2) 20,8 m/min (68,2 ft/min) 20,8 m/min (68,2 ft/min) 21,5 m/min (70,5 ft/min)
Maximum chain speed @ working load (2) 19,3 m/min (63,3 ft/min) 18,1 m/min (59,3 ft/min) 18,3 m/min (60,0 ft/min)
Motor cable size (3) 10 mm
2
(AWG7)
Protection circuit breaker (4) 20 A 30 A 20 A
Deck thickness (5) 20 ÷ 40 mm (3/4” ÷ 1” 9/16 ft)
Weight 10 kg - 22 lb 10,2 kg - 22,4 lb 10,2 kg - 22,4 lb
DIMENSIONS OF MODELS mm ( inch )