Operating Guide
QUICK BGA EA-H15 OPERATION MANUAL
Page22
12、QUICKSOFT brief instruction
12.1 operation interface
1. Operation interface: this interface reaction executive condition of flow , we can real-time operate by this
interface.
2. parameter of operation interface, be setting from “parameter testing interface”, in operation interface do
not need setting.
Parameter display: the parameter of this area do not be setting in “operation interface”, it can be setting in
parameter debug interface.
Flow select: express technology flow file which parameter have be edit.
K type sensor: KT1~KT3, only connect K type temperature sensor, can display temperature .
Flow curve display window: temperature curve of KT1-KT3, easy to real-time watch and curve analysis.
Flow status bar: this bar display flow status by colour, colour is corresponding to working colour .
Status bar: real-time display current state, contain communicate state (online/offline), the location of heat
head(up/middle/down), aligning arm location(external/middle/interior), head dissipation
(open/close),vacuum state(open/close).
Only when communicate state is online, we can control equipment auto carry out flow by software.
Working area: contain every working button “heat arm up”, “heat arm down”,“dissipation open/dissipation
K type sensor
Have two technology
mode, auto change
from solder and
desolder.
Parameter
display
Flow
curve
display
Flow
schedule
Status
bar