Operating Guide

BGA2015 OPERATION MANUAL
Page19
camera. When not in use, push it back, and the image displayed is got by IR camera.
9.2 Aligning Technics
1 Place the soldered component in jig, move PCB Fixture to make the vacuum pen aim at component on
the jig. Turn the Nozzle Controlling Knob to make nozzle move down to pick up component. The
component should be picked up from its center. As soon as the vacuum nozzle touches component, the
vacuum pump starts to work and pick up component.
2 Press Sucks key, prism auto judge stick out or not. Follow flow auto process.
PL-HEADsuckdown auto suck chip PL-HEADsuckupward prism auto stick out manual
aligningsee follow step.
3 Watch LCD picture satisfy our require or not, can adjust by keyboard, specific adjust refer to control
box instruction”.
4 Unscrew the PCB Fixing Knobs on the PCB Fixture to open PCB Clamp Bar. Fix the soldered PCB on
the PCB Fixture and adjust PCB’s position. Make the Monitor display the image of soldering point, and
make the images of soldering point and component in the same position. It is convenient for adjusting.
After roughly adjusting, screw down Fixture Fixing Knob to lock PCB Fixture to prevent it from sliding
right and left.
5 Align the component with two Adjustment Knobs and two Micro-adjustment Knobs. Make the images of
component solder pins and the soldering point on PCB overlap.
6 Press Sucks key, auto place.
7. Align the component with two Adjustment Knobs and two Micro-adjustment Knobs. Make the images of
component solder pins and the soldering point on PCB overlap.
10.Calibrating the system
Due to vibrations during transporting, it is necessary to calibrate the system before using. The steps are
shown as follows.
1 Insert the calibration plate into the PCB fixture and adjust the position, lock the fixture.
2 The vacuum tube section of vacuum pump will be treated as the calibration hole. (If it has nozzle, please
remove it.)
3 Press DOWN key to make PL-HEAD move down.
4 Turn “Nozzle Controlling Knob” to lower the calibration tube. Check whether the calibration tube
superposes exactly with the round hole on the calibration plate. If they aren’t superposition, please adjust
Micro-adjustment Knobs of fixture until the calibration tube and hole completely superpose. After
PL suck
PL Camera