Engineering Report

TESTING
INSPECTION
ENGINEERING
2118 Rheem Drive, Pleasanton, CA 94588 Phone (925) 462-5151 Fax (925) 462-5183
4770 Duckhorn Drive, Sacramento, CA 95834 Phone (916) 419-4747 Fax (916) 419-4774
One Embarcadero Center, Suite 535, San Francisco, CA 94111 Phone (415) 438-2357 Fax (415) 334-4747
246 30
th
St., Suite 101, Oakland, CA 94601 Phone (510) 444-4747 Fax (510) 835-1825
CONSTRUCTION
TESTING SERVICES
Lateral (Parallel to Rafter)
Figure 6: Lateral Parallel to Rafter Eccentric Load
Sample
Number
-
Rafter
Specific
Gravity
at
Moisture
Test
Rafter
Moisture
Content
[%]
Peak
Load
[lbs]
Deflection
at Peak
Load [in]
Failure Mode
1
0.500
11.6
440
3.2714
Post Crushing (Al Ductile) / Post
Hub Ruptured (Al Brittle)
2
0.531
12.1
430
3.4445
Post Crushing (Al Ductile)
3
0.514
12.5
435
3.4340
Post Crushing (Al Ductile)
4
0.457
12.0
445
3.4195
Post Crushing (Al Ductile)
Average
438
Applied
Load