QRail Installation
BI 7.2.3-46
Jul-2019, Rev 4.2
3
ANSI / UL 2703
The QRail system is ETL listed to UL 2703, Edition 1. Listing documents are available from the
website: www.quickmountpv.com. For additional information, contact Quick Mount PV.
UL 2703 requires that listed PV systems be labeled to indicate their compliance with UL 2703.
The QRail system includes labels a ixed to the QRail as shown in image 1.4.1.
1.4 Regulatory Information
Fire Class Resistance Rating (ANSI / UL 2703)
The QRail system is intended for roof mounting over a fire-resistant roof covering rated for the application. The QRail fire
rating is valid for the following:
Class A for Flush Mounted Steep Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules w/o
QSkirt
Class A for Flush Mounted Steep Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules w/ QSkirt
Class A for Flush Mounted Low Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules w/o QSkirt
Class A for Flush Mounted Low Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules w/ QSkirt
Class A for 5° and above Tilt Mounted Low Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules
w/o QSkirt
Class A for 5° and above Tilt Mounted Low Slope Applications when using Type 1 or Type 2, Listed Photovoltaic Modules
w/ QSkirt
This fire class rating requires installation procedures, which are in compliance with the included instructions. The QRail
system is intended for roof mounting over a fire-resistant roof covering rated for the application. The QRail fire rating is valid
for all roof slopes for Flush Mounted Systems and roof slopes equal to or less than 7° (1:12) for Tilt Mounted Systems. The
fire class rating is valid for systems installed at any height above the roof deck, with or without optional skirt.
Grounding & Bonding (ANSI / UL 2703)
This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific
module has been evaluated for grounding and/or mounting in
compliance with the included instructions.
Mechanical Load Rating (ANSI / UL 2703)
The QRail system has been mechanically tested according to UL 2703
Edition 1 to the following load ratings:
Downward Pressure: 10 PSF
Upward Pressure: 5 PSF
Down-Slope Load: 5 PSF
Image 1.4.1
QRail label placement
ANSI/UL 2703 require the presence of a label indicating the system Fire Class Rating
or information directing the user to the appropriate information. The QRail Fire Class
Rating label is located on each End Clamp as shown in Image 1.4.1.
Marking (ANSI / UL 2703)
QRail by Quick Mount PV®
Patent 9,147,986
Conforms to UL STD 2703
Fire Rating: see installation
manual for requirements
MFR: XXXX
5012866