QRail Installation

BI 7.2.3-46
Jul-2019, Rev 4.2
19
The internal QSplice is a floating splice, no attachments
necessary.
To join any rail using the Internal QSplice, join the rail sections
by sliding the splice into the end of the rail until the rivet head
comes into contact with the end of the rail.
Slide the other rail onto the splice until the end of the rail
comes into contact with the rivet head.
When re-installing the QRail Internal QSplices, insert the
splice backwards for optimal performance.
Internal QSplice Installation
NOTE!
To allow for thermal expansion/contraction,
spliced rail lengths should not exceed 45 feet
without a thermal break of 1/2 in. or more. Do
not install modules over this thermal break.
Image 5.2.6
Image 5.2.7
Image 5.2.8
Image 5.2.9
Image 5.2.10
DANGER
The outside edge of the
QClick must be installed
at least " from end or
rail at a splice location.
CAUTION
Spliced rails must have more than one
support on both sides of the splice.
Splices cannot be used in cantilever
areas.