2020 Installation Guide

BI 7.2.3-46
Feb-2021, Rev 14
27
Image 6.4.1
Inner module installation step 1
Image 6.4.2
Inner module installation step 2
Image 6.4.3
Inner module installation step 3
Image 6.4.4
Tighten clamp bolt
[144 in-lbs (16 N-m)]
DANGER
Material damage due to incorrect
mounting
Incorrectly fastened modules can fall and
become damaged.
Make sure the QClicks click in
securely
Ensure the modules are flush against
both sides of the clamp.
Observe and adhere to the
recommended torque specifications
6.5 Installing Additional Module Rows
Mounting steps:
Additional module rows are by repeating steps in sections 6.1-6.4.
NOTE!
Use of a spare module clamp QClick or other item as a spacing
gauge between the top of one row of modules and the bottom of
another can help provide a neat, aesthetically pleasing array.