2020 Installation Guide
BI 7.2.3-46
Feb-2021, Rev 14
25
Mounting Steps, Hidden End Clamps:
•
Aer installation of rails and prior to installation of the modules
slide the Hidden End Clamp into both sides approximately 4
inches from the end of the rail. See Image 6.3.4
•
Install first module insuring the module frame is flush with the
end of the rails. See Image 6.3.5
•
Slide Hidden End Clamp over until it fully engages with the
module flange. See Image 6.3.6
•
Tighten Hidden End Clamp bolt to 9 -lbs (12 N-m). See Image
6.3.7
•
At end of module row place final module in place (Do not tighten
mid clamps) and mark the edge of the module on the rail and
pick up module.
•
Cut Rail at the marked location
•
Replace module and tighten Mid Clamps
•
Slide final Hidden End Clamp over to fully engage flange of the
module
•
Tighten Hidden End Clamp Bolt to 9 -lbs (12 N-m). Place End
Caps onto rails
Image 6.3.4
Image 6.3.5
Image 6.3.6
Image 6.3.7
NOTE!
The QRail Hidden End Clamp is NOT a bonding solution and
therefore cannot be used on single modules. It must always be
installed in conjunction with at least one Bonding Mid Clamp.
NOTE!
When working at steep pitches it may be advantageous to
utilize Universal End Clamps while setting the module line. The
Hidden End Clamp can be tightened once the line is set and the
Universal End Clamp removed.