2020 Installation Guide

BI 7.2.3-46
Feb-2021, Rev 14
BI 7.2.3-46
Feb-2021, Rev 14
18
Internal Splice:
Install the internal splice with a " gap between the rails.
Aer installing the rails install the WEEB-BNDJMP8.0 across
the gap with T-bolts. Insure a loop is le to allow for thermal
expansion and contraction and torque T-bolts to [192 in-lbs
(22 N-m)].
Thermal Break
In cases where a thermal break is necessary it is recommended
to use the splices in conjunction with the Wiley WEEB-
BNDJMP8.0 to insure continuous bonding across the thermal
break.
CAUTION
Modules cannot be installed over
thermal break. The row of continuous
modules must end before the break
and a new row must start aer the
thermal break.
Images 5.2.12
WEEB-BNDJMP8.0 installed with Internal QSplice
Images 5.2.11
" thermal break with Internal QSplice
NOTE!
Align module a minimum of 1.2" from the end
of the rail unless utilizing a Hidden End Clamp.