Network Device, DL3800E User's Guide

4-16 DL3800E Inverse Multiplexer Users Guide July 9, 2001
4
To clear the report of all History Events, move the highlight bar to CLEAR
HISTORY and press Enter. Figure 4-6 is an example.
Figure 4-6 EVENT HISTORY MENU
Table 4-4 Alarm Level
Alarm Parameter Definition
Alarm Level:
Major
Minor
Idled
Status
Service affecting
Needs attention, not yet service affecting
Alarm condition has expired
Non-service-affecting event
Date and Time Date and time of the occurrence or expiration of the alarm/state
Address The address is the physical location
Device The device reporting the status and alarm condition (Unit #), and the type of device
(NET, DTE, or NODE)
Event Code Number designation for type of alarm or status condition. This number will be
useful when contacting the factory
Description Describes the event
Major 01/01/90 17:56:47 Unit: 1NET : 2(33)
Loss of Frame
Idled 01/01/90 17:56:58 Unit: 1NET : 2(13)
Loss of Frame Idled
DIGITAL LINK DL3800E SR 2.00.000 NODE 7:HOME 01/01/90
03:14:54 MN SELECTED DEVICE ADDRESS: 7.00.000NAME:HOME
EVENT HISTORY Exit Repeat Clear History Page 1
Idled 01/01/9009:02:10Unit 1NET 2 (29)
Yellow Signal Detected Idled
Major 01/01/9009:02:06Unit 1NET 2 (30)
Yellow Alarm
Status 01/01/9008:58:09Unit 1NET 2 (29)
Yellow Signal Detected
Idled 01/01/9008:58:01Unit 2NET 3 (29)
Yellow Signal Detected Idled
Minor 01/01/9008:56:24Unit 1Node (36)
ROM Checksum Failed