Product Brochure

7
Water-Gate | www.quickdams.com
1. Take any obstructions into consideration (pools, trees, sheds,
garden, etc.)
2. You will need a clear a path of at least 2ft (61cm) around the
perimeter of the structure that is being protected.
3. AclearpathwillberequiredtoplacetheWater-Gate
intoproperposition.Usechart(nextpage)todetermine
the amount of space needed, depending on the height
selected.
4. Use red line for measuring to determine
overall length needed.
5. Multiple pumps are required to pump rain
& seepage water away from the back end
oftheWater-Gate.
6. Corners can be created by folding unit properly. Curving
WaterGatesaroundbendswillmaximizelengthofunit.
7. Differentheightscanbejoinedbasedonheightofood
concerns.
8. Direction of water concern.
Key
2ft Clear path around Perimeter
Skirt length based on height selected
Measuring Line to determine Length Needed
1
2
3
4
5
6
7
Selection Guide
Location of Protection
TheWater-Gatesystemallowsa
complete or partial perimeter type
of protection by holding back the
oodwateratadistancefromwalls
rather than protecting individual
openings.
Sectional protection – Set up
betweentwowallsordikes/mounds
Semi perimeter protection – Set
up with angles or on a sloped terrain
360° protection – Complete on
allsides–Bothextremities(ends)
joined together
How to select the correct size & length
of Water-Gate
Water