Product Brochure
6 5
Water Force | www.quickdams.com Water Force | www.quickdams.com
1. Takeanyobstructionsintoconsideration(pools,trees,sheds,
garden,etc.)
2. Youwillneedaclearpathofatleast2ft(61cm)aroundthe
perimeterofthestructurethatisbeingprotected.
3. AclearpathwillberequiredtoplacetheWaterForce
intoproperposition.Usechart(nextpage)todetermine
theamountofspaceneeded,dependingontheheight
selected.
4. Useredlineformeasuringtodetermine
overalllengthneeded.
5. Multiplepumpsarerequiredtopumprain&seepagewater
awayfromthebackendoftheWaterForceduetorain,
seepage&downspouts.
6. Cornerscanbecreatedbyfoldingunitproperly.Curving
WaterGatesaroundbendswillmaximizelengthofunit.
7. Differentheightscanbejoinedbasedonheightofood
concerns.
Key
2ftClearpatharoundPerimeter
Skirtlengthbasedonheightselected
MeasuringLinetodetermineLengthNeeded
1
2
3
4
5
6
7
Selection Guide
Location of Protection
TheWaterForcesystemallowsa
complete or partial perimeter type
ofprotectionbyholdingbackthe
oodwateratadistancefromwalls
ratherthanprotectingindividual
openings.
Sectional protection – Set up
between two walls or dikes/mounds
Semi perimeter protection – Set
upwithanglesoronaslopedterrain
360° protection – Complete on
allsides–Bothextremities(ends)
joinedtogether
How to select the correct size & length
of Water Force
Water
Water
8
8
Water
Water
Increased
Elevation
Increased
Elevation
Water
How To Determine Required Length
1. Selectheightofprotectionneeded
a. Heightcanvarybasedonlandscaping-hills,
slopes,&waterowconcerns
b.Takeintoconsiderationlowestpointof
propertylineaswaterwillgravitatehere
2. Reviewchartbelowfordistancerequiredfor
placementofWaterForce
3. Walkaclearpatharoundperimetertoreviewany
obstructions
a.Increaselengthasneededtoavoidany
obstructionsorcreatingcorners
4. Measure red line ( ) distance to
determineoveralllength.(Seeimageon
previouspage)
a.Connectingedgejointsneedtobeatleast
5ft(1.5m)awayfromcorners
Remember to Use Water Pumps:
Any water collecting between the building and the
Water Force needs to be evacuated by pumps.
Things that can affect the quantity of water
behind the barriers are:
• Seepage rate of the barrier when full,
approximately 0.5-0.7gpm / ft (inside edge)
• Unpredictable volumes of rain
• Review gutter drainage & make a plan to redirect that
excess water over the other side of the Water Force
• Factors affecting the layout of the terrain. ie:
gravity, slopes, hills, etc.
Standard walking measuring tool
is recommended.
0
5 (1.5)
10 (3)
15 (4.6)
20 (6.1)
25 (7.6)
6in (15cm)
14in (35.5cm)
20in (50.8cm)
26.5in (67cm)
32in (81cm)
39in (1m)
50in (1.3m)
60in (1.5m)
6in (15cm)
14in (35.5cm)
20in (50.8cm)
26.5in (67cm)
32in (81cm)
39in (1m)
50in (1.3m)
60in (1.5m)
7
9
4
11
13
15
19
20
0
10 (3)
20 (6.1)
30 (9.1)
40 (12.2)
3.5
7.5
10.5
14
17
20.5
26.5
31.5
Length Needed
Additional Length Needed to
Create a Corner
Height of Protection
Skirt Length in Feet (Meters)
2ft (61cm) included
Feet (Meters) Needed
Height of Protection
Making corners requires folding material over itself.
As a result, additional length is needed based on height
Footprint of Skirt in Feet,
2ft (61cm) included
Unobstructed Area Needed
Additional Length Needed
to Create a Corner
Feet (Meters) Needed
Use laser measure tool to direct towards the
property to maintain the proper distance
while walking the perimeter while measuring
the length.