When po wered up the
LED is solid r e d with a
yellow flash, and
displaying 02.
The batte ry is very low,
and the charger is in a
slow charge pha s e until
the voltage rises to a
safe level before full
turn o n.
.
Leave connected, it may
take hours , but if the
voltage rises even a little
bit, it should recover,
and turn the charger f ull
on. (Do not allow your
batteries to deep
discharg e , it is the
number one cause of
premature battery
failure.)
The charger blows it’s
fuse, or branch circuit
fuse/circuit breaker as
soon as it’s switched on.
Charger is shor ted.
Contact factor y.
The charger blows the
branch circuit
fuse/circuit breaker a
short while after being
switched on.
The br a nch circ uit is too
small.
Relocate charger to a
branch circuit wi th a
heavier rating, or
remove other loads on
the circuit.
Batteries use water, ge t
hot, or s mell.
One or more dead cells.
Profile not set correctly.
Replace batteries. If
char ging in a seri es
string, it is best to
replace all the batteries
rathe r than mi x ne w
with old.
If shallow discharging,
check that the
gassing/absorption
profile is set to d1
After a full charge, the
batteries d ie quickly
The batteries are
sulfated.
Sometimes batteries can
be recovered. Leave the
charger on for some
hours, if the vol tage falls
and the current begi ns to
rise, it is a good sig n
they can recover under
normal chargi ng.