TU600A TU600A Technical Manual Version 1.
TU600A Content Content ......................................................................................................... 1 Introduction .................................................................................................... 7 Related Information .......................................................................................................... 7 Safety first......................................................................................................
TU600A Specifications .............................................................................................. 22 Product specifications .................................................................................................... 22 Connections: ............................................................................................................... 22 Internal temperature ranges: ......................................................................................
TU600A Corporate Office Trackunit APS Gasvaerksvej 24, 4 sal 9000 Aalborg Denmark. www.trackunit.com Copyright and Trademarks © 1998-2020, Trackunit APS. All rights reserved. Trackunit, Trackunit logo and Trackunit are trademarks of Trackunit APS, registered in the United States and in other countries. All other trademarks are the property of their respective owners. Release Notice This document is release v1.1 of the TU600A, Technical Manual.
TU600A RESELLER’S AND ITS CUSTOMERS’ SOLE RISK, AND TRACKUNIT SHALL HAVE NO LIABILITY WHATSOEVER IN CONNECTION THEREWITH. RESELLER SHALL INDEMNIFY AND HOLD TRACKUNIT AND ITS SUPPLIERS HARMLESS FROM ANY CLAIM BROUGHT AGAINST TRACKUNIT WHICH ARISES FROM RESELLER’S USE OR DISTRIBUTION OF THE PRODUCT IN CONNECTION WITH SUCH ENVIVRONMENTS OR APPLICATIONS.
TU600A US and Canada certificates: FCC ID: ZMF-TU600A IC: 9746A-TU600A EU certificate: CE mark by EU-Tec certificate: xxxxxxxxxxx United Kingdom (UK): UKCA mark by DOC Australia/New Zealand SDOC approval: RCM mark by SDOC from E7689 Japan certificates: [R] 003-200139 [R] 209-J00306 [T] D200116003 Bluetooth SIG registered: Declaration ID: D046156 Company identifier UUID: 2159 (0x086F) Automotive: KBA UN ECE R10 rev 5/1 certified : Trackunit TU600A, Technical Manual v1.
TU600A Introduction This document contains the installation guide for the (GSM / LTE cat-M1 / NB2-IOT / GNSS / BLE) product type series TU600A units. This manual is intended for use by system integrators, service providers and application developers (collectively, “Resellers”). It is not intended for end-users of the TU600A. Any end-user documentation is to be prepared and furnished by the resellers. This manual covers the TU600A with 60.
TU600A Interference Like all wireless devices, the TU600A may encounter electrical interference that may affect its performance. Avoid Body Contact with Device during Operation Do not operate the TU600A in direct contact with your body. Maintain at least 8 inches (20 cm) separation between the device and any parts of your body. Qualified Service Except for batteries and Subscriber Identification Module (SIM) card, the TU600A contains no user serviceable or replaceable parts.
TU600A The TU600A unit cannot be turned off after installation; however, the unit is mostly asleep waiting for either the wake-up timer or activity on the acceleration sensor. The unit operation can continue for approximately 3 to 4 days depending on the charging state of the backup battery. The TU600A unit is designed for vehicular use only. Electronic Devices Most modern electronic equipment is shielded from RF signals.
TU600A Posted Facilities The TU600A unit cannot be turned off after installation, so any vehicle, moving machinery, construction machinery installed with the TU600A etc. must not enter any facility where posted notices prohibit the use of wireless phones or two-way radios. Aircrafts FCC and FAA regulations prohibit using wireless phones while in the air. Do not carry the TU600A unit aboard an aircraft as it cannot be turned off.
TU600A Battery Safety Information Adhere to the following guidelines to avoid the risk of fire or explosion: 1. Dispose of the used battery according to the instructions provided with the battery. 2. Do not drop, puncture, disassemble, mutilate, or incinerate the battery. 3. Touching both terminals of a battery with a metal object will short circuit the battery. Do not carry batteries loosely if the contacts may touch coins, keys, and other metal objects (such as in pockets or bags). 4.
TU600A Delivered standard content The delivered standard package content includes the following items: 1 x (GSM/LTE M1/NB IOT/GPS)-unit of the model type TU600A 1 x Mounting cradle. 1 x Li-ion Battery PN 4233.0002 (May already be mounted inside the TU600A unit) Optional content for generic installation: 1 x Fuse with fuse holder for installation up to 24V DC/ (Max 1A) for TU600A units delivered with open cable ends.
TU600A Installing the unit Use location – Children not likely to be present This equipment design typically applies to commercial or industrial equipment expected to be installed in locations where only adults are normally present. Practical installation advice It is very important to be careful when installing the unit, as incorrect installation will reduce the quality of the GPS position reports (Ex.
TU600A Connections The connections depend on the type of vehicles / machines etc. in which the (GSM/LTE M1/NB IOT)/GPS unit is to be installed. Different variants of the TU600A device will have only a subset of the connections shown in the table below. Please contact your nearest sales office, distributor or “Reseller” for further information about the availability of other variants in your area.
TU600A Controller supports Bit Rates up to 1 Mbit/s. Physical Interface specification as referred to by ISO/11898-2. 120R CAN termination optional: Mounted, Not Mounted or controlled by Firmware (CAN configuration). The CAN Interface is only operational when supply voltage (12V / 24V / 48V) is present. Interface cannot operate on internal battery alone. M8 Connector: 1-Wire input The M8 3 pole connector contains 3 signals: 1-wire bus, 5V and Ground.
TU600A Functionality check Trackunit TU600A, Technical Manual v1.
TU600A “Verify my Trackunit” In order to control if the installation of the TU600A unit has been done correctly, it is possible to use the “Verify my Trackunit” tool. Trackunit TU600A, Technical Manual v1.
TU600A Troubleshooting Various error situations are listed below along with some possible solutions. Error Error description code F1 The unit does not answer the SMS command send to it. Possible solutions Verify if the SMS messages are sent to the correct GSM/LTE M1/NB IOT phone number. Check LED status; See the “Functionality check” chapter in this manual. If the TU600A unit has been delivered with the SIM card mounted. Contact Trackunit support.
TU600A Installation of the digital output According to the E1 certificate of the TU600A unit, it is prohibited under any circumstances to use this output to control any equipment that may influence the safety of the construction machinery and earth moving machines/vehicle operation and driving. The output must only be used to control comfort equipment. The example shows a 12V relay function with a 12V DC supply voltage. It is also possible to use a 24V relay with a 24V DC supply voltage etc.
TU600A SMS commands for output control Function Send SMS Return SMS Description Activation of the output MT OUT1=ON MTC ACK (SERIAL No.) OUT1 ON With this command the output is activated permanently. The output can be deactivated again using the “OFF” command. Deactivation of the output MT OUT1=OFF MTC ACK (SERIAL No.) OUT1 OFF With this command the output is deactivated.
TU600A For mounting the Trackunit TU600A in harsh environment, not covered by the compliance statements or areas where pressure cleaning is required the Trackunit HW shield PN 7402.9551 is required for protective mounting. Please order at Trackunit APS. Recommended fuse holders and fuses up to 48V supply voltages (Can be ordered at Trackunit APS): a. Supply voltage 12V/24V (Max 30A) i. ATO blade fuses (Max 32V/1A) used with Littelfuse FHAC0002SXJ fuse holder (Standard). ii.
TU600A When contacting technical support, please be prepared to provide the information listed below: Minimum Information Required for Technical Assistance If you or a user reports difficulty with a TU600A unit (i.e. no GPS fixes, not communicating, LED not working, etc.), it is helpful to retrieve directly from the unit all current configuration settings and the message log data etc., that is accessible by the technical support when they receive the following information about the unit. 2.
TU600A Charging time for an empty backup-battery 3 hours at 25 ºC Expected lifetime of the backup-battery 3 years Digital inputs 4 Digital outputs 1 1-Wire interface Optional CAN interface Optional Bluetooth 5 LE (wireless) Optional Internal temperature ranges: Charging or maintenance charging (With external DC supply voltage) 0ºC to +45ºC (If the temperature exceeds this range the charging is disabled, and the battery put into internal storage mode) In active running mode (Without externa
TU600A Pmax = 0.
TU600A Mechanical specifications Dimensions: Length: Width: Height: Cable length: 122.1 mm 45.65 mm (49 mm incl. mounting cradle) 18 mm (23 mm incl. mounting cradle) 170 – 180 cm Environmental class: IP67 (Standalone) IP66K, IP69K (Mounted with HW shield) Enclosure material: Non-flammable PP casing and ABS cable connector lid. Weight: 65 g (excluding the cable) Trackunit TU600A, Technical Manual v1.
TU600A Approvals and certificates The TU600A product is certified according to KBA (E1 mark), EU (CE mark), UK (UKCA mark) FCC, ISED, JATE/MIC ID (GITEKI mark): 10 R – 05 8766 FCC ID: ZMF-TU600A IC: 9746A-TU600A “The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Trackunit APS is under license. Other trademarks and trade names are those of their respective owners.
TU600A This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Déclarations selon le CFR 47 Sections 2.
TU600A Precaution: Trackunit recommends only mounting Output1 to starter motors through a relay and under no circumstances should Output1 be used to control engine shutdown during operation or any moving parts on the machine.
TU600A (EN/IEC 62368-1 + AC/3 + A11) 2014, 2015, 2017 Information and communication technology equipment safety EN/IEC 62133 {Ed2} 2012 Safety requirements for portable sealed secondary cells and for batteries made from them. CE and UKCA marking We, Trackunit Aps hereby declare that the TU600A product complies with the essential requirements of the RED Directive 2014/53/EU as stated by the EU Declaration of Conformity and the Radio Equipment Regulations 2017 – UK SI 2017 No. 1206.
TU600A This device is granted pursuant to the Japanese Radio Law (電波法) =当該機器には電波法に基づく、技術基準適合証明等を受けた特定無線設備を装着 している This device should not be modified (otherwise the granted designation number will become invalid) 本製品の改造は禁止されています。(適合証明番号などが無効となります。) Translated (For information only): This device is granted pursuant to the Japanese Radio Law (Radio Act) = The equipment is equipped with specified wireless equipment that has received a certificate of conformity with technical standards based on the Radio Law
TU600A Environmental compliance The TU600A are designed for compliance to the following environmental standards related to the intended use of the product: Standard Version Description A, B SAEJ1455:2017, EN/IEC 60068-2-1 2007 Cold SAEJ1455:2017, EN/IEC 60068-2-2 2006 Dry Heat IEC 61373, SAEJ1455:2017, EN/IEC 60068-2-27 2010 Shock SAEJ1455:2017, EN/IEC 60068-2-31 2008 SAEJ1455:2017, EN/IEC 60068-2-64 2008 Drop, free fall Random vibration IEC 61373, SAEJ1455:2017, EN/IEC 60068-2-64 2010 A
TU600A Environmental protection without HW shield: Trackunit TU600A, Technical Manual v1.
TU600A Environmental protection with use of HW shield: Trackunit Aps Gasvaerksvej 24, 4 sal DK-9000 Aalborg Denmark Trackunit TU600A, Technical Manual v1.