Test Standard
Damp heat, cyclic IEC 60068230
Rough handling IEC 60068231
Damp heat IEC 60068278
200 [7.87]
120 [4.72]
90 [3.54]
100 [3.94]
mm [in]
Figure 1 EGW501 dimensions
3.3 WXT536 Specifications
Table 14 WXT530 barometric pressure measurement performance
Property Description/Value
Observation range 500 ... 1100 hPa
Accuracy (for sensor element) at
600 … 1100 hPa
±0.5 hPa at 0 … +30 °C (+32 … +86 °F)
±1 hPa at −52 … +60 °C (−60 … +140 °F)
Output resolution 0.1 hPa / 10 Pa / 0.001 bar / 0.1 mmHg /
0.01 inHg
Units available hPa, Pa, bar, mmHg, inHg
Table 15 WXT530 air temperature measurement performance
Property Description/Value
Observation range −52 ... +60 °C (−60 ... +140 °F)
Accuracy (for sensor element) at +20 °C
(+68 °F)
1)
±0.3 °C (±0.54 °F)
Output resolution 0.1 °C (0.1 °F)
Units available °C, °F
1) A naturally aspirated radiation shield is applied which can aect readings in calm wind.
BWS500 Technical Specification M212450EN-A