Product Info

Smart Module Series
SC200R Series Hardware Design
SC200R_Series_Hardware_Design 23 / 125
LDO6_1V8
1)
125 PO
1.8 V output
power supply
Vnorm = 1.8 V
I
O
max = 150 mA
Power supply for
sensors, cameras,
and I2C pull-up
circuit.
If it is used, connect
an external
1.0–4.7 μF
capacitor to this pin
in parallel.
If it is not used,
keep it open.
LDO10_2V85 156 PO
2.85 V output
power supply
Vnorm = 2.85 V
I
O
max = 150 mA
Reserved power
supply.
If it is used, add a
1.0–2.2 μF bypass
capacitor.
If it is not used,
keep it open.
LDO17_2V85 129 PO
2.85 V output
power supply
Vnorm = 2.85 V
I
O
max = 450 mA
Power supply for
AVDD of LCM, TP,
sensors and
cameras.
If it is used, connect
an external
2.2–4.7 μF
capacitor to this pin
in parallel.
If it is not used,
keep it open.
LDO16_2V8 193 PO
2.8 V output
power supply
Vnorm = 2.8 V
I
O
max = 55 mA
Reserved power
supply.
If it is used, add a
1.0–2.2 μF bypass
capacitor.
If it is not used,
keep it open.
GND
Pin Name Pin No.
GND
3, 7, 12, 15, 27, 51, 62, 69, 76, 78, 85, 86, 88, 89, 120, 122, 130, 132, 135, 140,
143, 144, 149, 162, 171, 172, 176, 187–191, 202–204, 206–224, 226–231,
233–238, 240, 241, 243–245, 247, 248, 250, 251, 255, 256, 258, 259, 261, 266,
268, 269, 271–274