SC20-A_Manual_R1.0 Confidential / Released 36 / 57
Parameter
Description
Conditions
Typ.
Unit
LTE-FDD Band13 @23.3dBm
674.84
mA
LTE-FDD Band25 @23.1dBm
760
mA
LTE-FDD Band26 @23.2dBm
731
mA
7.6. Electrostatic Discharge
Table 20: Electrostatic Discharge Characteristics ( Temperature: 25, Humidity: 45%)
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
+/-5
+/-10
KV
All Antenna Interfaces
+/-5
+/-10
KV
USB Interfaces
+/-0.5
+/-1
KV
Other Interfaces
+/-0.5
+/-1
KV