Service Guide
LTE Standard Module Series
EG91_Series_Hardware_Design
70
/ 105
6.3. Operating and Storage Temperatures
The operating and storage temperatures are listed in the following table.
Table 30: Operating and Storage Temperatures
6.4. Current Consumption
The values of current consumption are shown below.
Table 31: EG91-AUX Current Consumption
13
Within operating temperature range, the module is 3GPP compliant.
14
Within extended temperature range, the module remains the ability to establish and maintain a voice, SMS, data
transmission, etc. There is no unrecoverable malfunction. There are also no effects on radio spectrum and no harm to radio
network. Only one or more parameters like P
out
might reduce in their value and exceed the specified tolerances. When the
temperature returns to the normal operating temperature levels, the module will meet 3GPP specifications again.
burst transmission level on EGSM900
I
VBAT
Peak supply current
(during transmission
slot)
Maximum power control
level on EGSM900
1.8 2.0 A
USB_VBUS
USB connection
detection
3.0 5.0 5.25 V
Parameter Min. Typ. Max. Unit
Operating Temperature Range
13
-35 +25 +75 ºC
Extended Temperature Range
14
-40 +85 ºC
Storage Temperature Range -40 +90 ºC
Description Conditions Typ. Unit
OFF state Power down 10 μA