The power-up scenario is illustrated in the following figure.
V
IL
≤ 0.5 V
V
IH
= 0. 8 V
VBAT
PWRKEY
≥ 500 ms
RESET_N
STATUS
(DO)
I nactive
Active
UART
I nactive Active
USB
≥
≥ 12 s
≥ 13 s
VDD_EXT
BOOT_CONFIG &
USB_BOOT Pins
About 100 ms
10 s
NOTE 1
≥ 100 ms. After this time, the BOOT_CONFIG
pins can be set to high level by external circuit.
Figure 12: Power-up Timing
1. Make sure that VBAT is stable before pulling down PWRKEY pin. The time between them is no less
than 30 ms.
2. PWRKEY can be pulled down directly to GND with a recommended 10 kΩ resistor if the module
needs to be powered on automatically and shutdown is not needed.
3. BOOT_CONFIG pins (SPI_CLK, USB_BOOT, PCM_CLK, PCM_SYNC) cannot be pulled up
before startup.
3.7.2. Turn off Module
Either of the following methods can be used to turn off the module normally:
Use the PWRKEY pin.
Use AT+QPOWD.
NOTE