Users Manual

LTE Standard Module Series
EC25 Hardware Design
EC25_Hardware_Design
44
/ 130
PWRKEY
4.7K
47K
≥ 500ms
10nF
Turn-on pulse
Figure 10: Turn on the Module by Using Driving Circuit
The other way to control the PWRKEY is using a button directly. When pressing the key, electrostatic
strike may generate from finger. Therefore, a TVS component is indispensable to be placed nearby the
button for ESD protection. A reference circuit is shown in the following figure.
Figure 11: Turn on the Module by Using Keystroke