Product Info
                                                                                                                                            Automotive  Module  Series 
   AG521R-NA  QuecOpen
Hardware  Design 
AG521R-NA_QuecOpen_Hardware_Design                                                                                      43  / 104 
PVIN
SS/TR
Module
PON_1
10K
0.78–1.89 V
Figure 13: Turn on the Module using PON_1 
If PON_1 is not used, it is recommended to connect it to the ground.   
3.7.3. Turn off Module 
Either of the following methods can be used to turn off the module: 
⚫  Normal power down procedure: Turn off the module using the PWRKEY pin. 
⚫  Normal power down procedure: Turn off the module using API interface. 
3.7.3.1.  Turn off Module Using PWRKEY 
Driving PWRKEY low for at least 2 s, the module will execute power-down procedure after PWRKEY is released. 
The power-off scenario is illustrated in the following figure. 
VBAT
PWRKEY
TBD
2  s
RUNNING
Power
-
down procedure
OFF
Module
Status
VDD_EXT
Figure 14: Power-off Timing 
NOTE 