Product Info

LTE Standard Module Series
EG95 Series Hardware Design
EG95_Series_Hardware_Design
84 / 99
WCDMA B1 -109.2 dBm -109.5 dBm NA -106.7 dBm
WCDMA B2 -109.8 dBm -111 dBm NA -104.7 dBm
WCDMA B5 -110 dBm -111 dBm NA -104.7 dBm
WCDMA B8 -110 dBm -111 dBm NA -103.7 dBm
LTE-FDD B1 (10MHz) -97.2dBm -98.9dBm -101.2dBm -96.3dBm
LTE-FDD B2 (10MHz) -97.7dBm -98.9dBm -101.7dBm -94.3dBm
LTE-FDD B3 (10MHz) -98.2dBm -99.1dBm -102.2dBm -93.3dBm
LTE-FDD B4 (10MHz) -97.7dBm -98.7dBm -101.2dBm -96.3dBm
LTE-FDD B5 (10MHz) -99.2dBm -99.7dBm -102.7dBm -94.3dBm
LTE-FDD B7 (10MHz) -96.7dBm -97.1dBm -99.7dBm -94.3dBm
LTE-FDD B8 (10MHz) -98.0dBm -98.4dBm -102.2dBm -93.3dBm
LTE-FDD B28 (10MHz) -98.7dBm -98.5dBm -101.7dBm -94.8dBm
LTE-FDD B66 (10MHz) -97.7dBm -98.8dBm -101.2dBm -95.8dBm
6.7.
Electrostatic Discharge
The module is not protected against electrostatic discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling and operation of any
application that incorporates the module.
The following table shows the modules electrostatic discharge characteristics.
Table 44: Electrostatic Discharge Characteristics (25 ºC, 45% Relative Humidity)
Tested Interfaces Contact Discharge
Air Discharge
Unit
VBAT, GND ±5 ±10 kV
All Antenna Interfaces ±4 ±8 kV
Other Interfaces ±0.5 ±1 kV