Product Info

LTE Standard Module Series
EG95 Series Hardware Design
EG95_Series_Hardware_Design
33 / 99
3.5.1.2. USB Application with USB Remote Wakeup Function
If the host supports USB suspend/resume and remote wakeup functions, the following three preconditions
must be met to let the module enter sleep mode.
Execute AT+QSCLK=1 command to enable sleep mode.
Ensure the DTR is held at high level or keep it open.
The hosts USB bus, which is connected with the modules USB interface, enters suspend state.
The following figure shows the connection between the module and the host.
Module
USB_VBUS
USB_DP
USB_DM
AP_READY
GND
Host
VDD
USB_DP
USB_DM
GPIO
GND
Figure 4: Sleep Mode Application with USB Remote Wakeup
Sending data to EG95 through USB will wake up the module.
When EG95 has a URC to report, the module will send remote wakeup signals via USB bus so as to
wake up the host.
3.5.1.3. USB Application with USB Suspend/Resume and RI Function
If the host supports USB suspend/resume, but does not support remote wake-up function, the RI signal is
needed to wake up the host.
There are three preconditions to let the module enter sleep mode.
Execute AT+QSCLK=1 command to enable sleep mode.
Ensure the DTR is held at high level or keep it open.
The hosts USB bus, which is connected with the modules USB interface, enters suspended state.
The following figure shows the connection between the module and the host.