6.3. Operation and Storage Temperatures
The operation and storage temperatures of the module are listed in the following table.
Table 38: Operation and Storage Temperatures
1.
1)
Within operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain
functions such as SMS and data transmission, without any unrecoverable malfunction. Radio
spectrum and radio network will not be influenced, while one or more specifications, such as Pout,
may exceed the specified tolerances of 3GPP. When the temperature returns to the normal operation
temperature levels, the module will meet 3GPP specifications again.
6.4. Current Consumption
The following table shows current consumption of BG95.
BG95-M4 3.8 V
I
VBAT
Peak supply
current (during
transmission slot)
Maximum power
control level on
EGSM900
BG95-M3/
BG95-M5
1.8 2.0 A
USB_VBUS USB detection
BG95-M1/
BG95-M2/
BG95-M3/
BG95-N1/
BG95-M4/
BG95-M5
5.0 V
Parameter Min. Typ. Max. Unit
Operation Temperature Range
1)
-35 +25 +75 ºC
Extended Temperature Range
2)
-40 +85 ºC
Storage Temperature Range -40 +90 ºC