Product Info
LPWA Module Series
BG95 Hardware Design
BG95_Hardware_Design 53 / 88
Table 18: Pin Definition of NET_STATUS
Table 19: Working State of
NET_STATUS
A reference circuit is shown in the following figure.
4.7K
47K
VBAT
2.2K
Module
NET_STATUS
Figure 21: Reference Circuit of the Network Status Indicator
3.14. STATUS
The STATUS pin is used to indicate the operation status of BG95. It will output high level when the
module is powered on.
The following table describes the pin definition of STATUS.
Pin Name Pin No. I/O Description Comment
NET_STATUS 21 DO Module network activity status indication 1.8 V power domain
Pin Name Logic Level Changes Network Status
NET_STATUS
Flicker slowly (200 ms High/1800 ms Low) Network searching
Flicker slowly (1800 ms High/200 ms Low) Idle
Flicker quickly (125 ms High/125 ms Low) Data transfer is ongoing
Always high Voice calling