Product Info
LPWA Module Series
BG600L-M3 Hardware Design
BG600L-M3_Hardware_Design 71 / 83
1)
LTE Cat NB2 receiving sensitivity without repetitions.
5.7 Electrostatic Discharge
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling and operation of any
application that incorporates the module.
The following table shows the electrostatic discharge characteristics of BG600L-M3 module.
Table 42: Electrostatic Discharge Characteristics (25 ºC, 45% Relative Humidity)
LTE-FDD B28 -107 /-100.8 -115.5/-107.5
LTE-FDD B66 -108/-101.8 -116/-107.5
LTE-FDD B71
Not
Supported
-115/-107.5
LTE-FDD B85 -106/-99.3 -115.5/-107.5
Network
Band Primary Diversity
Sensitivity (dBm)
GSM/3GPP
GSM
GSM850/EGSM900
Supported
Not
Supported
-107/-102
DCS1800/PCS1900
-107/-102
Tested Interfaces Contact Discharge Air Discharge Unit
VBAT, GND ±6 ±10 kV
Main/GNSS Antenna
Interfaces
±5 ±8 kV
NOTE