Product Info

LPWA Module Series
BG600L-M3 Hardware Design
BG600L-M3_Hardware_Design 65 / 83
5.3 Operation and Storage Temperatures
The operation and storage temperatures of the module are listed in the following table.
Table 37: Operation and Storage Temperatures
1.
1)
Within operation temperature range, the module meets 3GPP specifications.
2.
2)
Within the extended temperature range, the module remains the ability to establish and maintain
functions such as voice, SMS, data transmission, emergency call, etc., without any unrecoverable
malfunction. Radio spectrum and radio network will not be influenced, while one or more
specifications, such as P
out
, may undergo a reduction in value, exceeding the specified tolerances of
3GPP. When the temperature returns to the normal operating temperature level, the module will meet
3GPP specifications again.
5.4 Current Consumption
The following table shows current consumption of BG600L-M3 module.
Table 38: BG600L-M3 Current Consumption
USB_VBUS USB detection 1.3 1.8 V
Parameter Min. Typ. Max. Unit
Operation Temperature Range
1)
-35 +25 +75 ºC
Extended Temperature Range
2)
-40 +85 ºC
Storage Temperature Range -40 +90 ºC
Description Conditions Average Max. Unit
Leakage
1)
Power-off 12.5 - μA
PSM
2)
Power Saving Mode 4 - μA
NOTES