2.14 STATUS
The STATUS pin is used to indicate the operation status of BG600L-M3 module. It will output high level
when the module is powered on.
The following table describes the pin definition of STATUS.
Table 19: Pin Definition of STATUS
The following figure shows a reference circuit of STATUS.
Figure 22: Reference Design of STATUS
2.15 Behaviors of MAIN_RI
AT+QCFG="risignaltype","physical" command can be used to configure MAIN_RI behavior.
No matter on which port URC is presented, URC will trigger the behavior of MAIN_RI pin.
The default behaviors of MAIN_RI are shown as below.
Table 20:
Default
Behaviors of MAIN_RI
Pin Name
Pin No. I/O Description Comment
STATUS 13 DO Indicate the module’s operation status 1.8 V power domain
State Response
Idle MAIN_RI keeps in high level.