EG95_Hardware_Design 65 / 93
Voltage drop during
burst transmission
Maximum power control
level on EGSM900
400
mV
I
VBAT
Peak supply current
(during transmission
slot)
Maximum power control
level on EGSM900
1.8
2.0
A
USB_VBUS
USB connection
detection
3.0
5.0
5.25
V
6.3. Operation and Storage Temperatures
The operation and storage temperatures are listed in the following table.
Table 31: Operation and Storage Temperatures
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-35
+25
+75
ºC
Extended Temperature Range
2)
-40
+85
ºC
Storage Temperature Range
-40
+90
ºC
1.
1)
Within operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call* (emergency call is not supported on ThreadX
module), etc. There is no unrecoverable malfunction. There are also no effects on radio spectrum
and no harm to radio network. Only one or more parameters like Pout might reduce in their value and
exceed the specified tolerances. When the temperature returns to the normal operating temperature
levels, the module will meet 3GPP specifications again.
3. “*” means under development.