SC66_Hardware_Design 45 / 118
3.5. Turn on and off Scenarios
3.5.1. Turn on Module Using the PWRKEY
The module can be turned on by driving PWRKEY pin to a low level for at least 1.6s. PWRKEY pin is
pulled to 1.8V internally. It is recommended to use an open drain/collector driver to control the PWRKEY.
A simple reference circuit is illustrated in the following figure.
Turn on pulse
PWRKEY
4.7K
47K
>1.6s
R1
R2
Q1
R3
1K
Figure 6: Turn on the Module Using Driving Circuit
Another way to control the PWRKEY is using a button directly. A TVS component is indispensable to be
placed nearby the button for ESD protection. A reference circuit is shown in the following figure.
PWRKEY
S1
Close to S1
TVS
1K
Figure 7: Turn on the Module Using Keystroke