Product Info

LTE Module Series
BG96 Hardware Design
BG96_Hardware_Design 70 / 81
Table 32: Power Supply Ratings
6.3. Operation and StorageTemperatures
The operation and storagetemperatures of the modulearelisted in the following
table.
Table 33: Operation and StorageTemperatures
1.
1)
Withinoperation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like P
out
might reduce in their value and exceed the specified tolerances. When the temperature
Parameter Description Conditions Min. Typ. Max. Unit
VBAT VBAT_BB and VBAT_RF
The actual input voltages
must stay between the
minimum and maximum
values.
3.3 3.8 4.3 V
I
VBAT
Peak supply current
(during transmissionslot)
Maximum power control
level on EGSM900
1.8 2.0 A
USB_VBUS USB detection 3.0 5.0 5.25 V
Parameter Min. Typ. Max. Unit
OperationTemperature Range
1)
-35 +25 +75 ºC
Extended Temperature Range
2)
-40 +85 ºC
Storage Temperature Range -40 +90 ºC
NOTES