Product Info

LTE Module Series
BG96 Hardware Design
BG96_Hardware_Design 39 / 81
V
IL
0.5V
VBAT
PWRKEY
500ms
RESET_N
STATUS
(DO)
Inactive
Act ive
USB
NOTE
Inactive
Act ive
URAT
4.8s
4.2s
4.9s
Figure 8: Timing of Turning on Module
1. Make sure that VBAT is stable before pulling down PWRKEY pin. The time between them is no less
than 30ms.
2. Customers should expect to see ~0.8V on the PWRKEY pin, because of there is pulled up to an
internal voltage minus a diode drop in the Qualcomm chipset.
3.6.2. Turn off Module
Either of the following methods can be used to turn off the module:
Normal power down procedure: Turn off the module using the PWRKEY pin.
Normal power down procedure: Turn off the module using AT+QPOWDcommand.
3.6.2.1. Turn off Module Using the PWRKEY Pin
Driving the PWRKEY pin to a low level voltagefor at least 650ms, the module will execute power-down
procedure after the PWRKEY is released.
The power-down scenario is illustrated inthe following figure.
NOTE