Product Info
LPWA Module Series
BG95 Series Hardware Design
BG95_Series_Hardware_Design 73 / 106
6.3. Operating and Storage Temperatures
The operating and storage temperatures of the module are listed in the following table.
Table 39: Operating and Storage Temperatures
1.
1)
Within operating temperature range, the module meets 3GPP specifications.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain
functions such as SMS and data transmission, without any unrecoverable malfunction. Radio
spectrum and radio network are not influenced, while one or more specifications, such as Pout, may
exceed the specified tolerances of 3GPP. When the temperature returns to the normal operating
temperature levels, the module meets 3GPP specifications again.
6.4. Current Consumption
The following table shows current consumption of BG95 series module.
BG95-M4
3.2
3.8
4.2
V
BG95-MF
TBD
3.8
TBD
V
I
VBAT
Peak supply
current (during
transmission slot)
Maximum power
control level on
EGSM900
BG95-M3/
BG95-M5
1.8
2.0
A
USB_VBUS
USB detection
BG95
series
5.0
V
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-35
+25
+75
ºC
Extended Temperature Range
2)
-40
+85
ºC
Storage Temperature Range
-40
+90
ºC
NOTES