Product Info

LPWA Module Series
BG95 Series Hardware Design
BG95_Series_Hardware_Design 38 / 106
Table 7: VBAT and GND Pins
1)
For every VBAT transition/re-insertion from 0 V, the minimum power supply voltage should be higher
than 2.7 V. After the module starts up normally, the minimum safety voltage is 2.6 V. In order to ensure
full-function mode, the minimum power supply voltage should be higher than 2.8 V.
3.5.2. Decrease Voltage Drop
BG95-M1/-M2/-N1: The power supply range of BG95-M1/-M2/-N1 is 2.64.8 V. For every VBAT
transition/re-insertion from 0 V, the minimum power supply voltage should be higher than 2.7 V. After
the module starts up normally, the minimum safety voltage is 2.6 V. In order to ensure full-function
mode, the minimum power supply voltage should be higher than 2.8 V. Ensure the input voltage
never drop below 2.6 V.
BG95-M3/-M5/-M6: The power supply range of BG95-M3/-M5/-M6 is from 3.34.3 V. Please assure
the input voltage will never drop below 3.3 V.
BG95-M4: The power supply range of BG95-M4 is from 3.24.2 V. Ensure the input voltage never
Pin Name
Pin No.
Description
Module
Min.
Typ.
Max.
Unit
VBAT_RF
52, 53
Power supply for the
module’s RF part
BG95-M1/-M2/-N1
1)
2.6
3.3
4.8
V
BG95-M3/-M5/-M6
3.3
3.8
4.3
V
BG95-M4
3.2
3.8
4.2
V
BG95-MF
TBD
3.8
TBD
V
VBAT_BB
32, 33
Power supply for the
module’s baseband
part
BG95-M1/-M2/-N1
1)
2.6
3.3
4.8
V
BG95-M3/-M5/-M6
3.3
3.8
4.3
V
BG95-M4
3.2
3.8
4.2
V
BG95-MF
TBD
3.8
TBD
V
GND
3, 31, 48,
50, 54, 55,
58, 59, 61,
62, 6774,
7982,
8991,
100102
Ground
-
-
-
-
NOTE