User's Manual
LTE Module Series
BG96 Hardware Design
BG96_Hardware_Design Confidential / Released 63 / 71
Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
USB_VBUS
USB detection
3.0
5.0
5.25
V
6.3. Operation Temperature
The operation temperature is listed in the following table.
Table 31: Operation Temperature
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-35
+25
+75
ºC
Extended Temperature Range
2)
-40
+85
ºC
1.
1)
Within operation temperature range, the module is 3GPP compliant.
2.
2)
Within extended temperature range, the module remains the ability to establish and maintain a
voice, SMS, data transmission, emergency call, etc. There is no unrecoverable malfunction. There
are also no effects on radio spectrum and no harm to radio network. Only one or more parameters
like P
out
might reduce in their value and exceed the specified tolerances. When the temperature
returns to the normal operating temperature levels, the module will meet 3GPP specifications again.
6.4. Current Consumption
The information will be added in the future version of this document.
6.5. RF Output Power
The following table shows the RF output power of BG96 module.
NOTES