User's Manual
GSM/GPRS/GNSS Module Series
MC60 Hardware Design
MC60_Hardware_Design Confidential / Released 30 / 99
Figure 8: Reference Circuit for Power Supply of the GSM Part
It is suggested to control the module’s main power supply (VBAT) via LDO enable pin to restart the
module when the module becomes abnormal. Power switch circuit like P-channel MOSFET switch circuit
can also be used to control VBAT.
3.3.3.2. Reference Design for Power Supply of GNSS Part in All-in-one Solution
In all-in-one solution, the power supply of GNSS part is controlled by the GSM part through the
GNSS_VCC_EN pin. A reference circuit for the GNSS part power supply is given below. Please pay
attention to the electrical characteristics of GNSS_VCC_EN to match LDO’s EN pin. Please refer to
document [1] for details about the AT commands for GNSS control.
NOTE